Wednesday, December 5, 2012

Residential Extensions Now Made Easier to Comply


 
It’s been a while since my previous newsletter. What a hectic year!!
 
We assess extensions on a regular basis. I frequently get asked questions about different matters around this topic. So I thought to write this brief newsletter to clarify a few things.
 
The dwelling with the proposed extension does not have to achieve overall 6-star efficiency. The Building Commission issued a new Practice Note 2011-55 in May this year. A new process has been introduced which has made it easier for residential extensions to comply.
 
The process is below for alteration / extension works where it exceeds 50% of existing volume.

  1. The existing dwelling will be energy assessed. Most likely it will be a low star rating.
  2. The new alteration / extension works by default must be 6-star energy efficient.
  3. Then an overall required energy efficiency will be determined. This will be based on volume and star rating of both existing dwelling and proposed works. The verdict may be 4-star or 5-star as a minimum. Hence making compliance easier.  Refer to below table as an example.

New Picture

You can see from the above example, the project complies with 4.9-star efficiency, exceeding the minimum energy efficiency requirement of 4.4-star. In some cases, the Building Surveyor may ask for additional things such as: water tank or solar hot water or other improvements.
  
For further information, feel free to contact our office, Efficient Energy Choices, on 03 9390 2934 or via email at info@efficientenergychoices.com.au
  
  
Kind Regards,
 
 
Karim Ghobrial
 
 
 

Monday, May 14, 2012

Efficient Energy Choices on TV

Just in case you missed it, I was on Channel 9 yesterday afternoon on a show called On Display TV. The show was about practical ways to reduce your carbon footprint.

My client, Marie Wallin from Planet Architecture also came on to show case the architectural aspects of her energy efficient house, which was assessed at 7-stars by Efficient Energy Choices.

Watch it here!

http://www.youtube.com/watch?v=X7RjcR43Ccw&feature=youtube_gdata_player


Regards


Karim Ghobrial

Tuesday, April 17, 2012

6 STAR TO STAY!!

Most of you may be aware of the hot topic on the media yesterday about a proposal submitted to the Baillieu government   'to abandon 6-star thermal efficiency requirements for houses as part of its broader agenda for cutting government red tape'.

As of late yesterday, Ted Baillieu confirmed that he was not going to abolish the mandatory 6-star requirements.

To achieve 6-star is affordable, and the benefits far out-weigh the costs.  Reducing energy bills for heating and cooling, reducing water bills, and also increasing comfort within the home, are definitely the way to go!

For more information, click here:

http://www.theage.com.au/victoria/baillieus-aboutface-on-housing-20120416-1x3x2.html

Friday, March 30, 2012

Undercroft Insulation


Previously, I discussed the heat transfer losses in a dwelling.  To refresh your memory, at least 20% of heat transfer losses will be through a timber floor in a dwelling.  For a concrete slab on ground, those heat losses will be minimised. For more information, you may wish to refer to our earlier Blogs.

I want to take a quick look at the importance of insulating ceiling undercroft, in relation to first floor apartments as depicted in the photo below.

  

Without undercroft insulation, from my experience of rating hundreds of apartments, the average efficiency rating of apartments would be between 3 – 5 star efficiency. This may be satisfactory to the previous BCA 2010 regulations, but not compliant to the current BCA 2011.

Previous BCA 2010 applies to projects that were designed prior to 1 May 2011.  However, for projects designed post 1 May 2011, the minimum energy efficiency requirement for the current BCA 2011, is 5-star efficiency per each apartment.  The simplest way to ensure compliance to the current BCA 2011 is to insulate the undercroft by minimum R1.0. This can be in the form of insulation batts, Foilboard, foil or 20mm polystyrene products. These products must not compromise the fire integrity of the building.

The Table below summarises the info quick reference.


BCA Regulations
Undercroft Recommendations

Previous BCA 2010
Min 3-star per each apartment
Combined apartment average is 5-star
 
Can be achieved without undercroft insulation

Current BCA 2011
Min 5-star per each apartment
Combined apartment average is 6-star
 
Min R1.0 insulation for undercroft insulation

Wednesday, December 14, 2011

Carbon Carbon Carbon

As most of you have heard, last month the Clean Energy Bill 2011 which includes the introduction of Carbon Price, was passed in the Senate. The Clean Energy Bill is driving towards reducing Australia’s carbon emissions by 5% by the year 2020. The Clean Energy Bill will put an initial price of $23 per tonne of carbon (or equivalent greenhouse gases) emitted into the atmosphere from July next year. The initial price will increase by CPI to June 2015. From July 2015, the Carbon Price will float and the system will become an Emission Trading Scheme (ETS). The Carbon Price will vary dependent on the market from $15 and greater per tonne. This Clean Energy Bill will affect companies emitting over 125,000 tonnes of emission. ETS has already been introduced in Europe, and it’s on its way to being introduced in the USA, Canada and in Asia.

How will this affect householders?
Not directly. But indirectly through large carbon emitters who will be passing down their costs to consumers and householders. For example: the large electricity generators (i.e. Hazelwood, Loyang, etc...) will pay for their pollution, they will pass Carbon Price to the utility distributers (i.e. AGL, Red Energy, etc...). Then the utility distributers will pass it onto households.

The Carbon Price could also affect large industries, manufacturers, retailers, developers, etc... who will also be passing it onto consumers.  The estimated Carbon Price per household could be approximately $500 per year. The basic motto is: “if you pollute, you pay”.

Study on Carbon Price for efficient and inefficient dwellings

I conducted a study to assess the energy efficiency, the CO2 emissions, the estimated Carbon Price and the estimated energy bills (electricity and gas) of 4 typical Australian dwellings. The size of each typical dwelling is approximately 190m2. Refer to below Table.
1.     3-star efficiency dwelling: typical Australian dwelling with inefficient lighting, airconditioning units, appliances and hot water system.
2.     5-star efficiency dwelling: reasonable efficient lighting, airconditioning units, appliances and hot water system.
3.     6-star efficiency dwelling: efficient lighting the new BCA Section 3.12.5.5. Airconditioning units, appliances and hot water system.
4.     7-star efficiency dwelling: LED lighting, above average efficiency for airconditioning units, appliances and solar gas boosted hot water system.


As you can see from the figures, that the more energy efficient the dwelling, the less Carbon Price will be paid and vice versa.

These figures may be out by a third, based on government charges, different utility charges and operation by dwelling occupants.

These figures are for usage only. They do not include service and maintenance charges.
Fossil fuel prices have significantly increased over the last 5 – 10 years and will continue to significantly increase in the future. It would most definitely be advisable to increase dwelling’s energy efficiency including appliances and lighting.


Seven simple ways of increasing energy efficiency for your dwelling
1.     Change behaviour. Be more efficient with appliances, lighting, computers, TVs, etc...
2.     Install insulation where possible. Roof and floor insulation can make a huge difference.
3.     Install energy efficient lighting such as: LEDs and compact fluorescent.
4.     Have timers at home to automatically switch off some electrical items when not used.
5.     Have an onsite generator such as: solar panels for electricity or solar hot water. Solar hot water can save you up to seven months of gas bills.
6.     Install draft stoppers at external doors.
7.     Seal gaps and cracks.


More on these topics to follow next year....

Stay tuned!


Wednesday, November 2, 2011

Residential Building Mandatory Disclosure - A BIG DEAL!


It’s important for all of us to get our head around RBMD, as it may very well become a ‘big deal’ from next year!  To refresh your memory, RBMD is when a vendor is required to disclose their building’s energy efficiency performance at the time of either selling or leasing. This information may be incorporated in Section 32.
The Federal Government is now looking at introducing RBMD across all States and Territories.  Possibly to commence from May 2012, in any of the following forms (as per previous post):
1.     Full assessment: full thermal performance simulation and rating of the house to be conducted by a suitably accredited professional. It will assess building performance and potential upgrades and recommendations.
2.     Simplified thermal assessment: will have less focus on thermal performance. It will provide potential upgrades and recommendations.
3.     Online self-assessment: to use an online tool by making assumptions on a building’s performance based on data entered about the building’s components. This can be either completed by owner or a suitably accredited professional. This is less complex and general.

I recently read an interesting article by the Real Estate Institute of Victoria (REIV) which discussed RBMD. It was titled “Green Stars for Existing Homes”. The REIV commissioned a survey of 1000 people in 2007 and asked the question, ‘If you were looking for a property to purchase what would be your most important consideration?’ Number one was price, then location, then close proximity to amenities. “People were also asked a separate question about the importance of water and energy saving features. Reflecting natural concerns about the environment, a substantially high 93% said that those features were important to them.” Source: www.reiv.com.au
So if you are Designer, a Builder or an Owner, I encourage you to highly consider energy efficiency and sustainability in your designs, because the future buyer of that house may well ask for it.

Frequently Asked Question

Question: I have a dwelling with two toilets. Does the water tank need to be connected to one toilet or both? What is minimum water tank size?

Answer: In accordance with Practice Note 2011-55, the water tank needs to be connected to ALL toilet flushing in the dwelling. The minimum water tank size is 2000 litres for a dwelling. This applies to Class 1 buildings such as detached houses and attached units. However, it does not apply to Class 2 apartment developments.



Wednesday, August 31, 2011

Mandatory Disclosure could be at our doorstep!

Residential Building Mandatory Disclosure (RBMD) is when a vendor is required to disclose their building’s energy efficiency performance at the time of either selling or leasing. This will most likely be incorporated into Section 32. 

At present, RBMD has been in the ACT for at least a decade. The Department of the Environment, Water, Heritage and the Arts (DEWHA) commissioned the Australian Bureau of Statistics (ABS) to produce a statistical report modelling the relationship between “Energy Efficiency Rating and House Prices in the ACT”. The study found that energy efficient houses are likely to achieve a higher selling price than lesser energy efficient houses. Refer to our website www.efficientenergychoices.com.au to download the report.

At the moment, the Federal Government is looking to bring RBMD across all states and territories. The government has now commenced public consultation with relevant stakeholders and industry bodies.
RBMD is likely to commence from May 2012 and could be in any of the following form:
1.     Full assessment: full thermal performance simulation and rating of the house to be conducted by a suitably accredited professional. It will assess building performance and potential upgrades and recommendations.
2.     Simplified thermal assessment: will have less focus on thermal performance. It will provide potential upgrades and recommendations.
3.     Online self-assessment: to use an online tool by making assumptions on a building’s performance based on data entered about the building’s components. This can be either completed by the owner or a suitably accredited professional. This is less complex and general.
4.     Checklist assessment: the owner to do a checklist on building’s water and energy saving features. This list is to be disclosed at point of advertising.
5.     Mandatory rating with an opt-out feature: owner can opt-out not to assess their house and have their house rated at 0.
It is a hot topic at the moment, and I will keep you posted on the progress of RBMD.  Which option do you think will be introduced?

Thursday, July 21, 2011

More on Artificial Lighting

Artificial Lighting is still the hot topic since the recently released Building Commission Practice Note 2011-55 clause 8.1 and BCA 2011 Section 3.12.5.5, with the provision to address artificial lighting.

My focus here is on the adjustment of ceiling insulation R values (R4.0, R5.0, etc...), due to loss of ceiling insulation mainly from recessed downlights as the area of ceiling insulation will be reduced. The loss of insulation will be required to be compensated for by increasing the R-Value of insulation in the remainder of the ceiling. This criteria has been added in BCA Section 3.12.1.2(e). Refer to Table 3.12.1.1b taken from BCA.

Table 3.12.1.1b 2


Example 1:
For a dwelling with no downlights, the ceiling insulation adjustment will not be required. Ceiling insulation to remain as is.

Example 2:
For a dwelling with 20-off downlights.
Ceiling area penetrated is: 3.8
Assuming total ceiling area: 200
Percentage penetrated: 2.43%
Ceiling insulation R3.5 required for 6-star. Adjustment is: R4.8

This adjustment is to apply for single-storey dwellings. For double-storey dwellings, adjustment will apply to ceilings exposed to the elements.

FAQ: Does this ceiling insulation adjustment or quantity of downlights affect star rating?
Answer: NO. Ceiling adjustment does not affect the star rating energy efficiency.

 

Tuesday, May 31, 2011

The New Ticket Item - Artificial Lighting

The new ticket item in the recently released Building Commission Practice Note 2011-55 clause 8.1 and BCA 2011 Section 3.12.5.5, is the provision to address artificial lighting. It provides for the maximum power consumption by the lights in a space.
The artificial lighting provision is not to exceed the following:
·        5W/m2 for habitable spaces;
·        4W/m2 for verandah or balcony attached to a class 1 building;
·        3W/m2 for a class 10.
The above will apply to classes 1, 2 and 4, and will need to be clearly documented by the Energy Consultant or the Designer, and then provided to the relevant Building Surveyor.
There are a few items that remain the same after the introduction of 6-stars. Regulations for rainwater tanks and solar hot water systems have not changed. Either a rain water tank of minimum capacity of 2000 litres or a solar water heater system are still required when constructing new homes.
Sustainability Update
In accordance with the current Victorian Building Commission Practice Note 2011 – 55, an alteration or extension to an existing dwelling does NOT require either a rain water tank or solar hot water service. Clause 9.1.

Wednesday, April 27, 2011

6 Stars is around the corner!!

6-star energy efficiency is just around the corner for Victoria, starting from May 2011. If you are not aware, it already applies to other states such as: ACT, QLD and SA. This is another article to assist you in your design to improve energy efficiency in the most cost-effective way. We will be assessing insulation to garage ceilings. This is not a common practice by builders, but it will be prudent to consider.
Below is a simple house which has been assessed in different orientations with and without ceiling garage insulation.



From the above assessments, having garage ceiling insulation of R3.5, all orientations comply in accordance with 6-star energy efficiency. This is advisable and recommended for design, and can be very beneficial for volume builders’ master designs.
Sustainability Update
In accordance with the current Victorian Building Commission Practice Note 2008 – 55, an alteration or extension to an existing dwelling does NOT require either a rain water tank or solar hot water service.

Tuesday, March 15, 2011

Are you Ready for 6 Stars?

The 6-star regulations are almost here! I am aiming to bring you up to speed with the changes in this edition and in those to follow. 

One of the most frequent questions I get asked is: “When will the 6 star regulations commence?” The simple answer is, for Victoria they will commence from 1 May this year, as per BCA 2010 and the Building Commission. In other states such as: ACT, QLD and SA, they already commenced last year.

A point of confusion was whether 6 star energy efficiency is required, even if the design process was carried out prior to May this year. I called the Building Commission to clarify this, and they advised the following: that if there is substantial evidence that the design was carried out prior to May 2011, then a 5 star energy report carried out later on, will still be applicable and comply. However if there is no evidence, then a 6 star energy report will be required.

My focus from here on, will be about your designs complying with the new regulations.

When you’re designing new projects, consider the inherent thermal efficiencies of these wall types, ranked most efficient to least efficient.

This was briefly discussed in our September 2010 issue:
 

  1. Hebel Panels
  2. Polystyrene (EPS)
  3. Brick work
  4. Weatherboard
  5. FC Sheet Cladding
  6. Metal Cladding
Where possible, try to minimise either FC cladding and metal cladding. If possible, it is recommended to install them on either North and/or East facade, as they are the least thermal energy efficient. Also where possible, it is recommended to install Hebel panels and EPS on the thermal weak points on either south and/or west facade, as they are the most thermal energy efficient.

Another question I often get asked is about window frames. Which is more energy efficient, timber frame type or aluminium?Timber frame type are generally about 10% more energy efficient than aluminium window frames.

With the garage being north facing and standard insulation applied (refer drawings below):
house 2

 Drawings: courtesy of Simonds Homes, used by permission 
Energy efficiency rating with aluminium is: 5.9 stars
Energy efficiency rating with timber is: 6.0 stars (complies with new Code)

For further information, feel free to contact our office on 03 9390 2934 or by email info@efficientenergychoices.com.au


Visit our website www.efficientenergychoices.com.au

Talk again in the next edition, stay tuned!


Karim Ghobrial

Electrical Engineer; Energy and Sustainability Consultant

Wednesday, February 9, 2011

Energy Efficiency Rating for Apartments PART 2

Happy New Year to you and I hope you‘ve had a restful and safe Christmas break.
Following my previous newsletter (in Nov 2010), I thought to write more on the same topic because of the increasing demand on multi-level apartment projects, and Victorian government is encouraging higher density living.

To re-cap what I discussed last November, the below matrix summarises current and upcoming regulations from May 2011.

Energy Efficiency Requirements for Apartments for Classes 2 and 4
Comments and application for insulation
Current Regulations BCA 2009 Section J0.2
  • Individual apartment to be not less than 3 stars
  • Combined average of all apartments to be not less than 5 stars
  • Services not required
  • External walls to be insulated by minimum R1.5
  • Wall insulation between apartments not required, only optional
  • Highest floor to be insulated by minimum R2.5
  • Ceiling insulation between apartments not required, only optional
From May 2011 Regulations BCA 2010 Section J0.2
  • Individual apartment to be not less than 5 stars
  • Combined average of all apartments to be not less than 6 stars
  • BCA Section 3.12.5.5, artificial lighting requirement to be 5W/m2 for living areas
  •  External walls to be insulated by minimum R2.0
  • Wall insulation between apartments recommended minimum of R1.5
  • Highest floor to be insulated by minimum R3.5
  • Ceiling insulation between apartments recommended minimum of R2.5 



Is Section J required for multi-level apartments?

Short answer is Yes. Multi-level apartment buildings are considered as class 2 type. A brief Section J energy assessment will be required for the common areas and basement carparks (Class 7a). If the proposed building has either retail (Class 6) or commercial offices (Class 5), then these areas will require a full Section J energy assessment to include: fabric, glazing and services such as airconditioning and artificial lighting.

Sustainability Tip

To satisfy ESD requirements, energy efficient electrical appliances and efficient water fixtures to be within one point of the highest efficiency available on the market. This is to apply for items which are part of the base building works.

For further information, feel free to contact our office on 03 9390 2934 or by email info@efficientenergychoices.com.au

Visit our website www.efficientenergychoices.com.au

Karim Ghobrial
Electrical Engineer; Energy and Sustainability Consultant

Wednesday, November 17, 2010

Energy Efficiency Rating for Apartments

A few weeks ago, I was speaking to one of our valued Developers, who had questions about the energy efficiency rating for apartments.  It seems to be a grey area that is not clearly understood.  With the new regulations coming into effect May 2011, I thought to write this newsletter to dispel some of the mysteries.
In the table below, I have simplified the current and future requirements of the BCA.


Energy Efficiency Requirements for Apartments for Classes 2 and 4
Comments and application for insulation
Current Regulations BCA 2009 Section J0.2
·         Individual apartment to be not less than 3 stars
·         Combined average of all apartments to be not less than 5 stars
·         Services not required
·         External walls to be insulated by minimum R1.5
·         Wall insulation between apartments not required, only optional
·         Highest floor to be insulated by minimum R2.5
·         Ceiling insulation between apartments not required, only optional
From May 2011 Regulations BCA 2010 Section J0.2
·         Individual apartment to be not less than 5 stars
·         Combined average of all apartments to be not less than 6 stars
·         BCA Section 3.12.5.5, artificial lighting requirement to be 5W/m2 for living areas
·         External walls to be insulated by minimum R2.0
·         Wall insulation between apartments recommended minimum of R1.5
·         Highest floor to be insulated by minimum R3.5
·         Ceiling insulation between apartments recommended minimum of R2.5



Sustainability Tip
For building permit application, rainwater tank and solar hot water are not required for either the BCA or Building Commission requirement for class 2 and 4 buildings. However, they may be requested by Councils for planning applications as an ESD management requirement.
However, a rainwater tank or a solar hot water system is required for class 1 buildings (detached or units) as part of the Building Commission Practice Note 2008 – 55 requirement.
For further information, feel free to contact myself at Efficient Energy Choices, on 03 9390 2934 or via email at info@efficientenergychoices.com.au
Share your feedback or questions....
Talk again soon,

Karim Ghobrial
Electrical Engineer; Energy and Sustainability Consultant


Wednesday, October 20, 2010

NEWSFLASH - R2.5 to fit inside a 90mm Stud Wall

Over the last couple of years, I have spoken to many people who have found it difficult to find wall insulation batts of R2.5 to fit inside a 90mm stud wall.
Recently, I came across an email update from The Insulation Council of Australia and New Zealand (ICANZ). The members are Bradford and Fletcher insulation. Fletcher has just come out with these great pink batts products of R2.5 and R2.7 that can fit inside a 90mm stud wall. You can visit their website for more information http://www.insulation.com.au/.
When it comes to energy rating and assessment, additional wall insulation can make a huge difference and save on other material and labour costs on site to comply. I recently rated this large double-storey house of approximately 45 sq/m for a volume builder. The house (depicted below) has a large number of windows and I found it difficult to achieve 5 stars compliance.
Drawing: courtesy of Simonds Homes, used by permission.
The table below outlines our findings:

Ceiling Insulation
Wall Insulation
Energy Rating Efficiency
Comments
1st trial
R3.5 for upper floor
R2.0
4.8
Standard insulation throughout the house. Ceiling insulation only for upper floor
2nd trial
R3.5 per floor
R2.0
5.6
A significant increase for energy rating efficiency. Ceiling insulation per each floor would be required, adding additional material and labour costs. However, this cost is minimal in comparison to double-glazing or treated glazing.
3rd trial
R3.5 for upper floor
R2.5
5.0
A sufficient increase for energy rating efficiency to comply. Ceiling insulation only for upper floor. The only additional cost is to upgrade the wall insulation from R2.0 to R2.5. This is a minor cost increase in comparison to the 2nd trial.


As you can see from the above trials, R2.5 for wall insulation can be very effective for compliance, whether to current regulations for 5 stars or for upcoming regulations, 6 stars from May 2011. 
What are your thoughts on this one?
Cheers
Karim Ghobrial